is done as follows: the STORE button is pressed and held and to the searching coil a
definite type of nonferrous metal is approached, the indicators for the type of metal ID1
and ID2“ show the type of metal and against „accept / ACCEPT“ a definite figure is
depicted (as per the type of metal) - for example „accept: +12“. Then user can release
button STORE and will hear double beep! In this case the device will react only to
metals with own signal „+11, +12 or +13“, if for the parameter rng1 a value of 1 has
been chosen. If the value of rng1 increases to „3“, the device will react with a sound and
at signals of „+9 to +15“, i. e., the range increases with 3 more units under the
memorized value and 3 units over it. The device will not have sound indication of any
signals smaller than „+9― and greater than „+15.
The difference in the sub modes “accept and ACCEPT“ corresponding to auto
discr and AUTO DISCR“ expresses in that at auto discr the device memorizes only
the coefficient for purity ID1 of metal and the display shows for example: accept: +12“.
At an AUTO DISCR mode the device memorizes both coefficients for purity ID1 and
for magnetism ID2. An indication appears on the display, for example: A: +12, +10
(corresponding to ID1 = +12 and ID2 = +10). In this case the device will produce a
sound from located metal only if both memorized coefficients coincide. I. e., it will work in
a more precise way, but beside rng1, the value of rng2 will also be the one that will
matter, as ID2 is also taken into consideration. The setting of rng2 refers to the
indication of ID2 and is analogue to rng1“, but rng2 can change within the limits (1
10).
For example: if a metal with coefficients A: +12, +10 has been memorized and for
rng1 a value of „1“ has been chosen, and „3“ for rng2, the device will react only to
metals with signals from A: +11, +7to A: +13, +13“, or the ranges of location will be
for ID1 with 1 unit under and 1 unit above the memorized value +12, and for ID2 they
will be 3 units under and 3 units above the memorized value of „+10“.
Upon following pressing of VCO / DISCR the device is switched intoauto
discr / “AUTO DISCR with sub modes „reject / REJECT“, at which definite
undesired objects can be memorized and eliminated.